TEO-540-C1A Engine Maintenance Manual
Fault ID
11
Fault Group
2
Fault Name
[FAULT: DATA TLB]
Fault
Description
TLB data access exception
Fault Lamp
NTO
Root Cause
This fault indicates an invalid entry from the data translation lookup into the TLB
(Translation Lookaside Buffer) caused by a possible hardware issue (processor, memory
corruption)
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
12
Fault Group
2
Fault Name
[FAULT: DEBUG]
Fault
Description
Debug Module Exception
Fault Lamp
NTO
Root Cause
This fault indicates a debug exception was received from processor possibly due to a
hardware issue
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
13
Fault Group
2
Fault Name
[FAULT: GRA CORRUPT]
Fault
Description
GRA memory corrupt (Internal RAM)
Fault Lamp
NTO
Root Cause
This fault indicates a corrupted General On-Chip RAM area due to a processor issue. This
is the On-Chip RAM excluding the shared Reset Persistent RAM area.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.