TEO-540-C1A Engine Maintenance Manual
72-70
© 2018 Avco Corporation. All Rights Reserved
Page 284
November 2018
TEO-540-C1A Engine Maintenance Manual
Table 3 (Cont.)
Sensor Replacement Procedures
Sensor Name
Abbr.
ID
Qty.
Location
Replacement Instructions
Induction Air
Deck
Temperature
DECK-T
A041
1
Mounted in
the Y-pipe
attached to the
inlet of the
throttle body
(Figure 36)
1.
Disconnect the harness connector from
the sensor per instruction in the “Wiring
Harness Connectors” section in this
chapter.
2.
Remove the sensor from the induction
housing.
3.
Install the new sensor in the induction
housing.
4.
Refer to Standard Torque Tables in the
latest revision of the
Service Table of
Limits - SSP-1776
for torque values.
5.
Connect the harness connector to the
sensor per instruction in the “Wiring
Harness Connectors” section in this
chapter.
6.
Complete an operational ground check.*
Primary
Induction Air
Manifold
Temperature
Sensor
MAT-P
A035
1
(Figure 35)
1.
Disconnect the harness connector from
the sensor per instruction in the “Wiring
Harness Connectors” section in this
chapter.
2.
Remove and discard tie-wraps from the
fire shield on the sensor lead.
3.
Remove the fire sleeve from the sensor
lead.
4.
Remove the sensor.
5.
Install the new sensor.
6.
Refer to Standard Torque Tables in the
latest revision of the
Service Table of
Limits - SSP-1776
for torque values.
7.
Install the fire sleeve on the sensor lead.
8.
Install new tie wraps on the fire shield on
the sensor lead.
9.
Connect the harness connector to the
sensor per instruction in the “Wiring
Harness Connectors” section in this
chapter.
10.
Complete an operational ground check.*
Secondary
Induction Air
Manifold
Temperature
Sensor
MAT-S
A042
1
Mounted in the
induction
manifold
(Figure 35)
Same as MAT-P procedure.