![Lycoming TEO-540-C1A Скачать руководство пользователя страница 436](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585436.webp)
Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 406
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
26
Fault Group
4
Fault Name
[FAULT: RPRA INVALID
EXCEPTION]
Fault
Description
RPRA area invalid during exception
processing
Fault Lamp
NTO
Root Cause
This fault indicates an exception or interrupt occurred before the RPRA was tested and
initialized. This should prompt the boot code to initialize the RPRA. The fault was
triggered due to an ECU hardware issue.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
27
Fault Group
4
Fault Name
[FAULT: RPRA INVALID]
Fault
Description
RPRA area is not coherent
Fault Lamp
NTO
Root Cause
This fault indicates the RPRA contains an invalid data possibly due to an ECU hardware
issue.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
28
Fault Group
4
Fault Name
[FAULT: SPE]
Fault
Description
SPE Exception
Fault Lamp
NTO
Root Cause
This fault indicates a SPE (Signal Processing Engine) Floating Point data exception or
inexact result from floating-point instruction possibly due to an ECU hardware issue.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.