![Lycoming TEO-540-C1A Скачать руководство пользователя страница 512](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585512.webp)
Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 482
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
301
Fault Group
38
Fault Name
[FAULT: deck pressure cross-check]
Fault
Description
Deck Pressure crosscheck fault
Fault Lamp
FFL
Root Cause
This fault indicates the combined and inferred manifold pressure from throttle position
differ by more than a calibrated maximum threshold. The fault will become inactive if the
combined and inferred values converge
Troubleshooting Steps
1.
Are there any active deck pressure sensor slew rate, circuit or range faults? If yes, refer to
troubleshooting section for the active fault. If no, go to step 2.
2.
Contact Lycoming Engines.
Fault ID
302
Fault Group
38
Fault Name
[FAULT: fuel rail pressure cross-
check]
Fault
Description
Fuel Rail Pressure crosscheck fault
Fault Lamp
FFL
Root Cause
This fault indicates the Fuel rail pressure and inferred pressure differ by more than a
calibrated maximum threshold. The fault will become inactive if the combined and
inferred values converge
Troubleshooting Steps
1.
Are there any active fuel rail pressure sensor slew rate, circuit or range faults? If yes, refer to
troubleshooting section for the active fault. If no, go to step 2.
2.
Contact Lycoming Engines.
Fault ID
303
Fault Group
38
Fault Name
[FAULT: throttle position cross-
check]
Fault
Description
Throttle position crosscheck fault
Fault Lamp
FFL
Root Cause
This fault indicates the arbitrated and inferred throttle position differ by more than a
calibrated maximum threshold. The fault will become inactive if the arbitrated and inferred
values converge
Troubleshooting Steps
1.
Are there any active airflow discrepancy or crosscheck, sensor slew rate, circuit or range faults? If yes,
refer to troubleshooting section for the active fault. If no, go to step 2.
2.
Contact Lycoming Engines.
Fault ID
304
Fault Group
39
Fault Name
[FAULT: trip tacho time
discrepancy]
Fault
Description
Trip Tacho time discrepancy fault
Fault Lamp
None
Root Cause
This fault indicates trip tacho time differs between primary and secondary channel
possibly due to a memory corruption or one channel being down while the other was
running.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 2. If yes, go to step 3.
2.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
3.
Set ignition switch to on, do not start engine, complete step 2. Is fault still active? If no, sequence
complete. If yes, replace the ECU.