![Lycoming TEO-540-C1A Скачать руководство пользователя страница 430](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585430.webp)
Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 400
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
8
Fault Group
2
Fault Name
[FAULT: APP CODE ERROR]
Fault
Description
Application code area corrupt
Fault Lamp
NTO
Root Cause
This fault indicates either failed attempt of application code CRC (Cyclic Redundancy
Check) OR boot Code not in the expected memory range
OR
application code not in the
expected memory range
OR
failed application version check. This fault may also indicate
a broken hardware memory
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to reprogram the ECU. Is fault active or reprogram unsuccessful? If no,
go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
9
Fault Group
2
Fault Name
[FAULT: APP DATA ERROR]
Fault
Description
Application Calibration area corrupt
Fault Lamp
NTO
Root Cause
This fault indicates a possibility of either failed unit calibration block CRC check
OR
corrupted/failed memory. This fault may also indicate a broken hardware memory
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to reprogram the ECU. Is fault active or reprogram unsuccessful? If no,
go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
10
Fault Group
2
Fault Name
[FAULT: CACHE CORRUPT]
Fault
Description
CACHE memory corrupt
Fault Lamp
NTO
Root Cause
This fault indicates a possible CACHE memory corruption or failure
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.