![Lycoming TEO-540-C1A Скачать руководство пользователя страница 469](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585469.webp)
© 2018 Avco Corporation. All Rights Reserved
Appendix D
November 2018
Page 439
TEO-540-C1A Engine Maintenance Manual
Fault ID
162
Fault Group
21
Fault Name
[FAULT: 5V sensor supply 3 slew
rate]
Fault
Description
5V sensor supply 3 slew rate fault
Fault Lamp
None
Root Cause
This fault indicates 5V sensor supply 3 slew rate is greater than the calibrated maximum
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault still active or repetitive? If yes, go to step 2. If no, monitor engine operation
for the fault to repeat. If fault repeats, go to step 2.
2.
If fault is still active or repetitive, but is not affecting engine operation, contact Lycoming for further
assistance. If fault affects engine operation (ie… causes other faults), replace the ECU.
Fault ID
163
Fault Group
21
Fault Name
[FAULT: thermocouple offset
voltage slew rate]
Fault
Description
Thermocouple offset voltage slew rate
Fault Lamp
None
Root Cause
This fault indicates thermocouple offset voltage slew rate is greater than the calibrated
maximum
Troubleshooting Steps
1.
Run the engine in accordance with the engine and aircraft maintenance manuals. Vary the throttle
setting to allow the EGT, CHT, and TIT to increase and decrease with engine operation. Is the fault
active?* If yes, go to step 3. If no, go to step 2.
2.
Using the FST, download active and service fault logs, then clear fault logs and monitor engine
operation for the fault to repeat.
3.
If the fault is active and no other associated faults exist, replace the ECU.
*NOTE: This fault is usually associated with another thermocouple fault. If there are any other active
thermocouple faults, go to troubleshooting steps for the corresponding fault.
Fault ID
164
Fault Group
21
Fault Name
[FAULT: ECU supply voltage slew
rate]
Fault
Description
ECU supply voltage slew rate
Fault Lamp
None
Root Cause
This fault indicates ECU supply voltage slew rate is greater than the calibrated maximum
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault still active or repetitive? If yes, go to step 2. If no, monitor engine operation
for the fault to repeat. If fault repeats, go to step 2.
2.
If fault is still active or repetitive, but is not affecting engine operation, contact Lycoming for further
assistance. If fault affects engine/ECU operation (ie… causes other faults, affects performance), replace
the Power Box.