Chapter 3 Configuring the OC-3 Mode Ports and Channels Using the Console
Viewing the Channelized OC-3 Statistics
3-52
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Severely Err. Fram.
Sec.
Default:
0
Range: 1–9999999999
Format: Numeric
Displays severely errored framing seconds contain one
or more severely errored frame defects. A severely
errored frame defect occurs when four errored frame
alignment cells are contiguous. The severely errored
frame defect is terminated when two contiguous error-
free frame cells are detected on the section layer.
CodingViolations
Default:
0
Range: 1–9999999999
Format: Numeric
Displays a bipolar violation or excessive zeros error
event on the incoming connection.
Line Statistics Panel (display only)
Status
Default:
NoAlarm
Range: N/A
Format: Predefined
Displays whether there is an alarm condition or not on
the line layer.
NoAlarm
No alarm condition is present on the line layer.
Alarm
An alarm condition is present on the line layer.
Err. Sec
Default:
0
Range: 1–9999999999
Format: Numeric
Displays a second with at least one of the following:
•
Path code violations
•
Controlled slip events
•
Detected alarm indication signal (AIS) defects
•
Bipolar violations
Severly Err. Sec.
Default:
0
Range:
Format: Numeric
Displays severely errored framing seconds at the line
layer. A second containing one or more severely
errored frame defects. A severely errored frame defect
is the occurrence of four contiguous errored frame
alignment cells. The severely errored frame defect is
terminated when two contiguous error free frame cells
are detected.
Coding Violations
Default:
0
Range: 1–9999999999
Format: Numeric
Displays a bipolar violation or excessive zeros error
event on the incoming connection.
Unavailable Sec
Default:
0
Range: 1–9999999999
Format: Numeric
Displays the number of seconds the interface is
unavailable at the onset of ten contiguous severely
errored seconds. The interface becomes available at the
onset of ten contiguous seconds with no severely
errored seconds.
Path Statistics Panel (display only)
Width
Default:
Module
dependent
Range: N/A
Format: Predefined
Displays the type and speed of the SONET/SDH path.
Table 3-24. 1-Port Channelized OC-3/STM-1 CES Port Statistics Window Field Descriptions (Continued)
Field Name
Field Value
Description
Содержание 23N12
Страница 175: ......
Страница 176: ...Copyright 2005 Lucent Technologies All rights reserved Part Number 569M2A11003D1...