Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Viewing the Channelized STM-1 Statistics
4-56
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Figure 4-23. Channelized STM-1 Port Statistics Window
Table 4-25. Channelized OC-3/STM-1 Port Statistics Window Commands
Command
Function
Continuous Update
Updates the values in the fields every second.
Reset Statistics
Sets all field values to
0
.
Go Back to Port Configuration
Redisplays the Port and Channel Configuration window.
Table 4-26. 1-Port Channelized OC-3/STM-1 CES Port Statistics Window Field Descriptions
Field Name
Field Value
Description
Section Statistics Panel (display only)
Status
Default:
NoAlarm
Range: N/A
Format: Predefined
Displays whether there is an alarm condition or not on
the section layer of the connection.
NoAlarm
No alarm condition is present on the line section.
Alarm
An alarm condition is present on the line section.
Err. Sec.
Default:
0
Range: 1–9999999999
Format: Numeric
Displays a second with one or more coding violations
at the section layer of the transmission, or one or more
incoming defects: (for example, a severely errored
frame (SEF), a LOS, an AIS, or LOP).
Severely Err. Sec
Default:
0
Range: 1–9999999999
Format: Numeric
Displays a second with 32 or more coding violations in
the section, line, and/or path layer of the transmission;
or a second during which at least one or more incom-
ing defects (for example, LOS, AIS, and so on) on the
section layer has occurred.
Содержание 23N12
Страница 175: ......
Страница 176: ...Copyright 2005 Lucent Technologies All rights reserved Part Number 569M2A11003D1...