255-700-714R11.0
3-27
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Chapter 3 Configuring the OC-3 Mode Ports and Channels Using the Console
Configuring a Port with One or More Channels, (Accessing the Channelized OC-3 Virtual DS1 Channel Configuration
The port configuration has been applied.
4
Remain on this window and continue with the next procedure, “Config-
uring a Port with One or More Channels, (Accessing the Channelized
OC-3 Virtual DS1 Channel Configuration Window) (Strapping)”.
End
Configuring a Port with One or More Channels, (Accessing
the Channelized OC-3 Virtual DS1 Channel Configuration
Window) (Strapping)
Begin
Configuring a Port with Several Channels, Part 2, (Accessing the Channelized OC-3 Virtual DS1 Channel Configuration Window)
1
On the Channelized OC-3 STS1 Port Configuration window (see
Figure 3-10), select an unconfigured channel on the right panel of the
window. The Channelized OC-3 Virtual DS1 Channel Configuration win-
dow is displayed (see Figure 3-11). Table 3-8 describes the commands on
the window. Table 3-9 describes the configurable fields on the window.
Note:
You must have selected the value
Enabled
in the Channelization
field on the Channelized OC-3 Virtual DS1 Port Configuration win-
dow (see Figure 3-11).
2
In the Interface Type field, select one of the following types of interface
types from Table 3-9.
If you select
CircuitEmulation
as the interface type, the Signaling field
displays. If you want to strap any channels together, do not change the
Signaling field default, which is
Disabled
.
3
Begin the strapping process by using the arrow key to highlight an Avail-
able DS0 that you want to strap with other DS0s in the [Available DS0s]
field.
4
Press Enter. This action displays an
X
below DS0 number. Repeat steps 3
and 4 until you have strapped all the DS0s you want to strap for the
selected channel. (In the sample configuration shown in Figure 3-13,
channels 1 through 5 have been strapped).
5
Select the
Apply Configuration
command and press Enter.
In the [DS0s Strapped] field (display only), the values for the DS0s you
just selected are displayed (see Figure 3-14). This first group of strapped
DS0s are now shown as Channel 1 on the Ch OC-3 Virtual DS1 Channel
Configuration window.
6
To strap together more DS0s for another channel in the selected port,
reselect the Channel field and enter the next channel number you want
to strap.
7
Repeat step 2-6 for the rest of the available DS0s (or as many as you
want to use).