Chapter 3 Configuring the OC-3 Mode Ports and Channels Using the Console
Configuring J1 Trace
3-36
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
2
After applying the
Port Configuration
command in the OC-3 SM Port
Configuration window (see Figure 3-8), select the
Configure STS1 Vir-
tual Port 1
.
The Channelized OC-3 SM STS1 Port Configuration window is displayed
(see Figure 3-17). Table 3-6 describes the commands on the window.
Table 3-7 describes the fields on the window.
3
Remain on the same window, select the
J1 Trace Configuration
com-
mand.
The Higher Order Path Trace - J1 Byte Configuration window is dis-
played (see Figure 3-18). Table 3-17 describes the commands on this
window. Table 3-18 describes the configurable fields on this window.
4
Select the values for the fields on the window in Figure 3-18 from
Table 3-18.
5
Select the
Apply Configuration
command and press Enter.
End
Table 3-16. Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions
Field Name
Field Value
Description
Loopback Config Default:
NoLoop
Range: N/A
Format: Predefined
Specifies whether and what kind of loopback configuration
is used on the signal on this connection.
NoLoop
Indicates that no loopback is to be done on the signal.
LocalLoop
Indicates that the received signal at this interface enters
through the backplane, is looped through the device, and
exits through the backplane.
LineLoop
Indicates that received signal at this interface does not pass
through the device but is looped back out through the exter-
nal port.
Transmit Clock
Default:
LocalTim-
ing
Range: N/A
Format: Predefined
Indicates what type of synchronization is used by the inter-
face to maintain proper data flow through the PSAX system
and the remote devices connected to the system.
LocalTiming
Selects a synchronization source (CompositeClock, T1BITS,
E1ETSI, CompositeClockDS0A, Freerun, or LineTiming) that
is provided through the Stratum 3–4 module. For GR-303
configuration, select this default.
LoopTiming
This value is currently not supported.
Содержание 23N12