Chapter 3 Configuring the OC-3 Mode Ports and Channels Using the Console
Configuring the OC-3 Working and Standby Module Pair
3-32
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
APS/MSP Commands (Left Panel)
Apply APS/MSP Command
Runs the command you selected in the APS Command or
MSP Command field.
Configuration Commands (Right Panel)
Apply APS/MSP Parameters
Applies the configuration values for both the primary and the
standby OC-3c APS or MSP modules.
Reset APS/MSP Display
Resets the fields to the last set of saved values.
Go Back to Port Configura-
tion
Redisplays the Port and Channel Configuration window.
Table 3-14. Channelized OC-3STM-1 APS/MSP Configuration Window Commands (Continued)
Command
Function
Table 3-15. Channelized OC-3 MM APS Configuration Window Field Descriptions
Field Name
Field Value
Description
APS Statistics Panel (display only)
Working Port SF
Dur
Default:
00000000
Range: 0–99999999
Format: Numeric
(seconds)
Displays the amount of time in seconds that the work-
ing port has had a failed signal (SF) above the selected
threshold bit error rate. This value changes dynami-
cally for the life of the connection.
Working Port SD
Dur
Default:
00000000
Range: 0–99999999
Format: Numeric
(seconds)
The amount of time in seconds that the working port
has had a degraded signal (SD) above the selected
threshold bit error rate. This value changes dynami-
cally for the life of the connection.
Prot. Port SF Dura-
tion
Default:
00000000
Range: 0–99999999
Format: Numeric
(seconds)
The amount of time in seconds that the protection port
has had a failed signal (SF) above the selected thresh-
old bit error rate. This value changes dynamically for
the life of the connection.
Prot. Port SD Dura-
tion
Default:
00000000
Range: 0–99999999
Format: Numeric
(seconds)
The amount of time in seconds that the protection port
has had a degraded signal (SD) above the selected
threshold bit error rate. This value changes dynami-
cally for the life of the connection.
Switch Over Counts Default:
00000
Range: 0–99999
Format: Numeric
(integer)
The number of times that switchover of active status
from one module to the other in the pair has occurred.
This is an incrementing value displayed as an integer.
TX K1/K2
*
Default:
00/00
Range: 99/99
Format: Hexadecimal
bytes
For the transmit port, the protocol for the APS chan-
nel, carried in the K1 and K2 bytes, in the signal in the
protection line. The K1 byte is used to indicate a
request by a channel for a switch action. The K2 byte is
used to indicate the bridging actions performed at the
LTE, and the provisioned architecture and mode of
operation