255-700-714R11.0
4-15
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Configuring All Channels on a Port (Channelization Disabled)
APS or MSP
Configured
Default:
Unpro-
tected
Range: N/A
Format: Predefined
Specifies whether two module(s) are to be set up in adjacent
odd- and even-numbered slots for APS/MSP protection
mode or not.
Unprotected
Select this value if the module is being configured as a stan-
dalone unprotected module, and
not
being paired with
another module in a 1+1 protection configuration.
Working
Select this value when the module is being paired with
another identical 1+1 APS-compatible module (single-mode
or multimode with the same operating mode (see Operating
Mode field)) in a 1+1 APS configuration. Before selecting
this value, the modules must be installed as an adjacent,
consecutively numbered, pair in the PSAX chassis. To verify
the module placement, return to the Equipment Configura-
tion window and locate the modules. The 1+1 protection
modules can only be configured when they are installed in a
consecutively numbered odd/even order, such as slots 9 and
10, 11 and 12, and so on, and not in an even/odd numbered
order, such as slots 10 and 11. In this arrangement, either
module can serve as the primary (working) module or the
standby (protection) module. After selecting this value, click
the
Apply Port Configuration
command. The [Working
Slot] and [Protection Slot] fields appear with the appropriate
slot numbers listed, the status of the modules, and the APS
Configuration window is available through the
Configure
APS
command.
[WorkingSlot]
Default:
Active
Range: N/A
Format: Predefined
Displays the slot number and status of the working module
in a 1+1 APS configured module pair. This field is displayed
only when the APS Configured field is set to
Working
.
Active
Indicates the working module is functioning properly and
the protection module is in standby.
Standby
Indicates the working module is in standby and the protec-
tion module is active.
[ProtectionSlot]
Default:
Standby
Range: N/A
Format: Predefined
Displays the slot number and status of the protection mod-
ule in a 1+1 APS configured module pair. This field is dis-
played only when the APS Configuration field is set to
Working
.
Active
Indicates the protection module is functioning properly and
the working module is in standby.
Standby
Indicates the protection module is in standby and the work-
ing module is active.
Table 4-5. Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions (Continued)
Field Name
Field Value
Description