Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Configuring J1 Trace
4-40
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Configuring J1 Trace
The J1 and J2 byte configuration ensures that data reaches the correct desti-
nation and also helps in long term data monitoring.
Perform the following procedure to configure the J1 Trace on the Channel-
ized STM-1 SM Port Configuration window.
Begin
1
From the STM-1 SM Port Configuration Window (see Figure 4-8), set the
J1 Trace field to
Enabled
(see Table 4-18).
Note:
From the Channelized STM-1 SM Port Configuration window,
verify that the J1 Trace field is set to
Enabled
.
2
After applying the
Port Configuration
command in the STM-1 SM Port
Configuration window (see Figure 4-8), select the
Configure AU-3
Virtual Port 1
.
Protection SD BER Default:
TenToMinus5
Range:
Format:
Specifies the signal-degraded bit error rate (SD BER) value
on the MSP protection module port.
TenToMinus5
10
-5
(lowest quality threshold, indicates a “signal
degraded” (SD) status).
TenToMinus6
10
-6
(lower than 10
-7
quality threshold).
TenToMinus7
10
-7
(lower than 10
-8
quality threshold).
TenToMinus8
10
-8
(low quality).
[Working Line]
Default:
NoAlarm
Range: N/A
Format: Predefined
Indicates the status of the port on the working module.
NoAlarm
The port is functioning with no alarms.
ModuleFailure
The module has failed.
[Protection Line]
Default:
NoAlarm
Range: N/A
Format: Predefined
Indicates the status of the port on the protection module.
NoAlarm
The protection line is ready if needed; no alarm condition
is present.
ModuleFailure
The protection module has failed.
[MSP Status]
NoFailure
Indicates whether a switchover has occurred from one
module to the other module in the pair.
Table 4-17. Channelized STM-1 SM MSP Configuration Window Field Descriptions (Continued)
Field Name
Field Value
Description