CDM816D WHEEL LOADER
67
4.
Use and Maintenance of the Supporting Battery in the Loader and Related Notes
After the battery is installed in the whole loader, since the circulation time of the new loader in and out
the factory differs, the actual charge capacity of the battery and the discharging degree are also
different, so the discharge degree of the battery shall be watched out closely when the loader is on
sale, and the concentration of electrolyte solution and end voltage shall not be lower than the
acceptable level of discharge rules.
Fig.3-26 Schematic Diagram of Electrical System
1.
Battery charging
Charge the battery in time when the density of battery electrolyte is lower than 1.2g/cm (25 0) or single
voltage is below 1.75V.
Starter motor
Master power
switch
Charging generator
Regulator
Working lamp
Hour meter
Combination lamp
Instrument
lamp (7
lamps in
parallel)
Signal lamp
Flasher
Left direction indicator lamp
Right direction indicator lamp
Parking lamp
switch
Ceiling lamp
Wiper
Brake lamp
switch
Low pressure
alarm buzzer
Pressure
alarm switch
Monotone horn
Starter fan
Heater
Water temperature
gauge
Oil temperature
gauge
Water temperature sensing plug
Oiltemperature sensing plug