SFA-5000 • SFA-10000 EtherCAT
bits 7 … 11
Not used
Flash memory error
bit 12
Wrong parameters loaded from flash memory at power on.
bits 13 … 15
Not used
6509-00 Offset value
[Unsigned32, ro]
As soon as you activate the preset, the current position value of the encoder is
saved on this object. The offset value is then used in the preset function in order
to calculate the encoder position value to be transmitted. To zero set the value
in this object you must upload the factory default values (see the
For any further information on the preset function and the meaning and use of
the related objects
refer to page 74.
NOTE
Always save the new values after setting in order to store them in the non-
volatile memory permanently. Use the
on page 63.
Should the power supply be turned off all data that has not been saved
previously will be lost!
MAN SFA_5000_10000_EC E 1.0.odt
6 - EtherCAT® interface
79 of 84