SFA-5000 • SFA-10000 EtherCAT
5.2.2 Synchronous with DC (SYNC0)
In the left pane of the
TwinCAT System Manager
main window press the
Box
(Lika EtherCAT SFA-XXXXX-EC)
item: some tabbed pages for configuring and
managing the device will appear in the right pane. Enter
DC
page.
Select the
Synchronous with DC (SYNC0)
option in the
Operation Mode
box.
Then press the
Advanced Settings...
button. The
Advanced Settings
window
will appear.
In the section tabbed
SYNC 0
set the cycle time next to the
Sync Unit Cycle
box; sync time is calculated as multiple (or sub-multiple) of the value set in the
Sync Unit Cycle (µs)
item right above.
For any further information on the Synchronous with DC operation mode please
refer to the “Synchronous with DC SYNC0” section on page 54 and to the
MAN SFA_5000_10000_EC E 1.0.odt
5 - Quick reference (TwinCAT) 35 of 84