SFA-5000 • SFA-10000 EtherCAT
EXAMPLE 2
SFA-
10000
-
EC
-
8192
-M12 using a custom resolution (
= 1)
Stroke per turn of the drum = 200 mm (7.874”)
Physical resolution per turn = 13 bits = 8,192 cpr
Max. number of physical revolutions = 14 bits = 16,384 revolutions
Custom resolution per turn =
(example)
= 8,192,000 information (example)
Custom number of encoder revolutions =
=
4,096
Linear resolution = 0.1 mm = 100 µm
Max. number of turns of the drum = 50
Max. measuring length = 10,000 mm (393.7”)
Number of information = 100,000
3.4 Maintenance
The measuring system does not need any particular maintenance; anyway it has
to be handled with the utmost care as any delicate electronic equipment. From
time to time we recommend the following operations:
•
the unit and the wire have to be cleaned regularly using a soft and clean
cloth to remove dust, chips, moisture etc.; do not use oil to clean the
wire.
MAN SFA_5000_10000_EC E 1.0.odt
3 - Mechanical installation