SFA-5000 • SFA-10000 EtherCAT
Transmitted
position
=
x Real position
≤
6501-00 Hardware counts per revolution
The total custom resolution in the
must be less than or equal to the maximum physical value (
6502-00 Hardware number of turns
).
Default = 0
is currently enabled, you can read the
WARNING
When you enable the scaling function (bit 2
objects that are consistent with the physical values. In the
case of inconsistent values, the system will warn about the wrong
parametrization and fault condition by means of the dedicated objects and
visually by means of the diagnostic LEDs.
WARNING
Every time you enable the scaling function and/or change the scaled values (see
the
objects), then you are required to set a new preset value (see the
object).
6001-00 Units per revolution
[Unsigned32, rw]
WARNING
This object is active only if the bit 2
object is set to ”=1”; otherwise it is ignored and the
system uses the physical values (
6501-00 Hardware counts per revolution
6502-00 Hardware number of turns
) to calculate the position
information.
This object sets a custom number of distinguishable steps per revolution
(custom singleturn resolution).
MAN SFA_5000_10000_EC E 1.0.odt
6 - EtherCAT® interface
69 of 84