EM58 • HS58 • HM58 POWERLINK
6500 Operating status
[Unsigned16, ro]
Bit
Function
bit = 0
bit = 1
0
CW
Clockwise
CCW
counter
clockwise
1
not used
2
Disabled
Enabled
3 … 15
not used
Code sequence
It shows whether the code sequence is set to clockwise (CW) or counter-
clockwise (CCW). If the bit is “=0” the output encoder position value has been
set to increase (count up information) when the encoder rotates clockwise; if
the bit is “=1” the output encoder position value has been set to increase when
the encoder rotates counter-clockwise. To set the code sequence to either CW or
CCW you must set the bit 0
object to 0 / 1. For any further information on setting and using
the counting direction refer to the
object on page
Scaling function
It shows whether the scaling function is disabled or enabled. If the value is “=0”
the scaling function is disabled (i.e. the system uses the resolution physical
values -
- to
calculate the position information); if the value is “=1” the scaling function is
enabled (i.e. the system uses the custom values -
6002 Total measuring range in measuring units
- to
calculate the position information). To disable / enable the scaling function you
must set the bit 2
to 0 / 1. For any further information on setting and using the scaling function
refer to the
6501 Singleturn resolution
[Unsigned32, ro]
WARNING
This object is active only if the bit 2
object is set to “=0”; otherwise it is ignored and the system uses
the custom values (
6001 Measuring units per revolution
measuring range in measuring units
) to calculate the position information.
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface
98 of 108