0001 0196 * = singleturn
encoder, HS58 series
0002 0196 * = multiturn
encoder, EM/HM58 series
00
000F 4240
EMxxx13/16384-PL-xx * =
EM58 series
HSxxx18-PL-xx * =
HS58 series
HMxxx16/16384-PL-xx * =
HM58 series
Device dependent
Device dependent
1018-01
NMT_IdentityObject_REC.VendorID_
U32
0000 012E
1018-02
NMT_IdentityObject_REC.ProductCo
de_U32
0000 1000 = HM58 series
0000 1001 = EM58 series
0000 1002 = HS58 series
1018-03
NMT_IdentityObject_REC.RevisionNo
_U32
0000 0001
1018-04
NMT_IdentityObject_REC.SerialNo_U
32
FFFF FFFF
1020-01
CFM_VerifyConfiguration_REC.Conf
Date_U32
0000 0000
1020-02
CFM_VerifyConfiguration_REC.ConfT
ime_U32
0000 0000
1030-01
NMT_InterfaceGroup_0h_REC.Interf
aceIndex_U16
0001
1030-02
NMT_InterfaceGroup_0h_REC.Interf
aceDescription_VSTR
LIKA ROTACOD
EMxxx13/16384-PL-xx 1.0 *
= EM58 series
LIKA ROTACOD HSxxx18-PL-
xx 1.0 * = HS58 series
LIKA ROTACOD
HMxxx16/16384-PL-xx 1.0 *
= HM58 series
1030-03
NMT_InterfaceGroup_0h_REC.Interf
aceType_U8
06
1030-04
NMT_InterfaceGroup_0h_REC.Interf
05DC
MAN EM58_HS58_HM58 PL E 1.1.odt