EM58 • HS58 • HM58 POWERLINK
6.12.1 Communication Profile Area objects (DS 301)
1000 NMT_DeviceType_U32
[Unsigned32, const]
It contains information about the device type. The object describes the type of
device and its functionality.
Default = 0001 0196h = singleturn encoder, HS58 series
0002 0196h = multiturn encoder, EM58 and HM58 series
1001 ERR_ErrorRegister_U8
[Unsigned8, ro]
This object provides error information. The POWERLINK device maps internal
errors into this object. The structure of the error register is as follow:
Bit
Meaning
0
Generic error
1
Current
2
Voltage
3
Temperature
4
Communication error
5
Device profile specific
6
Reserved (always 0)
7
Manufacturer specific
If a generic error occurs, the bit 0 will be set to "1".
If a specific error occurs, the corresponding bit (except 6) will be set to “1”.
Default = 00h
1006 NMT_CycleLen_U32
[Unsigned32, rw]
This object defines the communication cycle time interval expressed in µs. This
period defines the SYNC interval. The object should be set by the system
configuration.
Default = 1000000 (min. = 200, max. = 2147483)
1008 NMT_ManufactDevName_VS
[String64, const]
It contains the manufacturer device name.
Default = EMxxx13/16384-PL-xx
=
EM58 series
HSxxx18-PL-xx
=
HS58 series
HMxxx16/16384-PL-xx
=
HM58 series
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface