EM58 • HS58 • HM58 POWERLINK
1030-08 NMT_InterfaceGroup_0h_REC.InterfaceAdminState_U8
[Unsigned8, rw]
It shows the current administration state of the interface.
It can be:
0 = Down
1 = Up
Default = 1 (min. = 0, max. = 1)
1030-09 NMT_InterfaceGroup_0h_REC.Valid_BOOL
[Boolean, rw]
It specifies whether the data of this object is valid. If the value is TRUE (1) the
data of this object is valid. If the value is FALSE (0) the data of this object is
invalid.
Default = TRUE (1) (min. = FALSE (0), max. = TRUE (1))
1300 SDO_SequLayerTimeout_U32
[Unsigned32, rw]
The object provides a timeout value in milliseconds (ms) for the connection
abort recognition of the SDO sequence layer.
The connection is detected as broken if the opposite node is shut down or
disconnected from the network. The connection is considered broken when no
acknowledgement is received within the timeout set in this object.
Default = 15000 (min. = 100, max. = FFFF FFFFh)
1800-00 PDO_TxCommParam_00h_REC
[Unsigned8, const]
These indices describe the communication attributes of the TPDO channels.
Mapping version and address information are provided. As a CN has only one
TPDO channel, only the first index
PDO_TxCommParam_XXh_REC
is
implemented on a CN. This sub-Index contains the number of entries.
Default = 2
1800-01 PDO_TxCommParam_00h_REC.NodeID_U8
[Unsigned8, ro]
It contains the Node ID of the PDO target. It is 0 (not used) for CNs.
Default = 0
1800-02 PDO_TxCommParam_00h_REC.MappingVersion_U8
[Unsigned8, ro]
Compatibility of TPDO channels and corresponding RPDO channels may be
ensured by PDO mapping version handling. PDO Mapping can be variable
(configurable) or static (unchangeable). Variable mapping may be dynamically
modified by the application, even under operation. Static mapping is pre-
defined and may not be modified in any way. The version info is transmitted by
the Master or producer with every PDO transporting PReq and PRes frame. A
MAN EM58_HS58_HM58 PL E 1.1.odt