EM58 • HS58 • HM58 POWERLINK
1018-04 NMT_IdentityObject_REC.SerialNo_U32
[Unsigned32, const]
It provides the Serial Number of the device.
Default = FFFF FFFFh (=not used)
1020-00 CFM_VerifyConfiguration_REC
[Unsigned8, const]
The following objects hold device local configuration date and time. This sub-
Index contains the number of entries.
Default = 2
1020-01 CFM_VerifyConfiguration_REC.ConfDate_U32
[Unsigned32, rw]
It holds the local configuration date. It contains the number of days since
January 1, 1984.
Default = 0 (min. = 0, max. = FFFF FFFFh)
1020-02 CFM_VerifyConfiguration_REC.ConfTime_U32
[Unsigned32, rw]
It holds the local configuration time. It contains the number of milliseconds (ms)
since midnight.
Default = 0 (min. = 0, max. = FFFF FFFFh)
1030-00 NMT_InterfaceGroup_0h_REC
[Unsigned8, const]
The following objects are used to configure and retrieve parameters of the
network interfaces (physical or virtual) via SDO. This sub-Index contains the
number of entries.
Default = 9
1030-01 NMT_InterfaceGroup_0h_REC.InterfaceIndex_U16
[Unsigned16, ro]
Interface index of the physical interface. This number is the index number
subtracted by 102Fh. The POWERLINK node that adds an interface generates the
respective value.
Default = 1 (min. = 1, max. = 10)
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface
76 of 108