EM58 • HS58 • HM58 POWERLINK
5 Quick reference
5.1 Before starting
Lika encoders are
CN devices
(Controlled Nodes e.g. Slaves: nodes without the
ability to manage the SCNM mechanism, see on page 63) and comply with the
“EPSG Draft Standard 301 Ethernet POWERLINK Communication Profile
Specification Version 1.2.0”. as well as with the CANopen Profiles “DS301
CANopen Application Layer and Communication Profile” and “DS406 Device
Profile for Encoders” according to the POWERLINK specifications. They require a
MN device
installed in the POWERLINK network (Managing Node, e.g. a Master:
a node capable to manage the SCNM mechanism, see on page 63).
5.1.1 Network identity
Lika POWERLINK encoders use the following identity settings:
Identity Name:
Vendor ID
Object:
1018-01 NMT_IdentityObject_REC.VendorID_U32
Setting:
0000 0012Eh
Identity Name:
Device Type
Object:
Setting:
0001 0196h
HS58 series
0002 0196h
EM58, HM58 series
Identity Name:
Product Code
Object:
1018-02 NMT_IdentityObject_REC.ProductCode_U32
Setting:
1000h
HM58 series
1001h
EM58 series
1002h
HS58 series
Identity Name:
Manufacturer Device Name
Object:
Setting:
EMxxx13/16384-PL-xx
EM58 series
HSxxx18-PL-xx
HS58 series
HMxxx16/16384-PL-xx
HM58 series
5.1.2 Network and communication settings
The
MAC address
of the device is always reported in the label applied to the
encoder enclosure. See on page 32.
The
POWERLINK Node ID
is set via hardware using the DIP A DIP switch
located inside the encoder enclosure. The default value is 1. See on page 32.