EM58 • HS58 • HM58 POWERLINK
1C0B-00 DLL_CNLossSoC_REC
[Unsigned8, const]
The following objects are used to monitor “Loss of SoC” (Start of Cycle frame)
error symptoms detected by a CN. The record consists of a cumulative counter
and a threshold counter data object and its threshold data object. This sub-
Index contains the number of entries.
Default = 3
1C0B-01 DLL_CNLossSoC_REC.CumulativeCnt_U32
[Unsigned32, rw]
The cumulative counter is incremented by 1 every time a “Loss of SoC“ error
symptom occurs. Its value monitors all “Loss of SoC” error symptoms that are
detected by the CN.
Default = 0
NOTE
If the unit is reset, this attribute is set to its default value.
1C0B-02 DLL_CNLossSoC_REC.ThresholdCnt_U32
[Unsigned32, ro]
The threshold counter shall be incremented by 8 every time a “Loss of SoC” error
symptom occurs and decremented by 1 at every cycle without reoccurance of
the error. Its value monitors the quality of network in relation to the “Loss of
SoC” error occurrence.
Default = 0
1C0B-03 DLL_CNLossSoC_REC.Threshold_U32
1C0B-02 DLL_CNLossSoC_REC.ThresholdCnt_U32
threshold, a defined action proceeds and
DLL_CNLossSoC_REC.ThresholdCnt_U32
is reset to 0.
Threshold Counting can be deactivated by setting
DLL_CNLossSoC_REC.Threshold_U32
to 0. If Threshold Counting is
deactivated, no error reaction will occur.
Default = 15 (min. = 0, max. = FFFF FFFFh)
1C0FB-00 DLL_CNCRCError_REC
[Unsigned8, const]
The following objects are used to monitor CRC (Cyclic Redundancy Check)
errors. The record consists of a cumulative counter and a threshold counter data
object and its threshold data object. This sub-Index contains the number of
entries.
Default = 3
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface