EM58 • HS58 • HM58 POWERLINK
1F8D-01 NMT_PResPayloadLimitList_AU16.PResPayloadLimit
[Unsigned16, rw]
Each sub-Index in the array corresponds to the node with the Node ID equal to
the sub-Index. The sub-Index value is valid only if there is an isochronous node
assigned to the Node ID by index
NMT_NodeAssignment_AU32
[sub-Index]
bits 0 and 8 (see page 81).
Sub-Index
C_ADR_MN_DEF_NODE_ID
indicates the payload size of the PRes
frame issued by the MN.
Values should be equal on all nodes of the segment.
Default = 36 (C_DLL_ISOCHR_MAX_PAYL)
1F93-00 NMT_EPLNodeID_REC
[Unsigned8, const]
The following objects store the devices' POWERLINK Node ID. This sub-Index
contains the number of entries.
Default = 2
1F93-01 NMT_EPLNodeID_REC.NodeID_U8
[Unsigned8, ro]
This sub-Index holds the device's current POWERLINK Node ID. It is provided by
hardware settings (DIP switch), refer to the “4.8 POWERLINK Node ID: DIP A”
section on page 32. By default the POWERLINK Node ID is set to “1”.
Default = 1 (min. = 1, max. = 254)
1F93-02 NMT_EPLNodeID_REC.NodeIDByHW_BOOL
[Boolean, ro]
This sub-Index displays the Node ID setup mode of the device. It is set up during
system initialisation.
•
TRUE (1) = the device's POWERLINK Node ID is set up exclusively by HW.
•
FALSE (0) = the device's POWERLINK Node ID is set up exclusively by SW.
Default = TRUE (1) (min. = 0 (FALSE), max. = 1 (TRUE))
1F98-00 NMT_CycleTiming_REC
[Unsigned8, const]
The following objects provides node specific timing parameters, that influence
the POWERLINK cycle timing. This sub-Index contains the number of entries.
Default = 8
1F98-01 NMT_CycleTiming_REC.IsochrTxMaxPayload_U16
[Unsigned16, const]
It provides the device specific upper limit for payload data size expressed in
bytes of isochronous messages to be transmitted by the device.
On all nodes, the sub-Index limits the size of the PRes frame issued by the node
(sub-Index
1F98-05 NMT_CycleTiming_REC.PresActPayloadLimit_U16
, refer
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface