EM58 • HS58 • HM58 POWERLINK
4 Electrical connections
WARNING
Power supply must be turned off before performing any electrical connection!
4.1 Connection cap
WARNING
Do not remove or mount the connection cap with power supply switched ON.
Damage may be caused to internal components.
The DIP switch meant to set the encoder node ID is located inside the
connection cap. Thus you must remove the connection cap to access it.
NOTE
Be careful not to damage the internal components when you perform this
operation.
To remove the connection cap loosen the two screws
1
. Please be careful with
the internal connector.
Always replace the connection cap at the end of the operation. Take care in re-
connecting the internal connector. Tighten the screws
1
using a tightening
torque of approx. 2.5 Nm.
WARNING
You are required to check that the encoder body and the connection cap are at
the same potential before replacing the connection cap!
Figure 1 - Removing the connection cap
MAN EM58_HS58_HM58 PL E 1.1.odt
Electrical connections
29 of 108