EM58 • HS58 • HM58 POWERLINK
PDO mapping version value of 0 indicates that there is no mapping version
available.
Default = 0
1A00-00 PDO_TxMappParam_00h_AU64
[Unsigned8, ro]
These indices describe the mapping of the objects contained in TPDO payload to
the Object Dictionary entries. As a CN has only one TPDO channel, only the first
index
PDO_TxMappParam_XXh_AU64
is implemented on a CN. This sub-Index
contains the number of active entries.
Default = 2
1A00-01 PDO_TxMappParam_00h_AU64.ObjectMapping
[Unsigned64, ro]
It describes the mapping of the
TPDO. The entries are interpreted according to the following table (all values in
hex):
Length (bit) Offset (bit)
res
Sub-Index
Index
LLLL
OOOO
rr
ss
IIII
e.g.
0020
0000
00
00
6004
Map 20h = 32bit starting at offset 0 to
Default = 0020 0000 0000 6004h
1A00-02 PDO_TxMappParam_00h_AU64.ObjectMapping
[Unsigned64, ro]
It describes the mapping of the
TPDO. The entries are interpreted according to the following table (all values in
hex):
Length (bit) Offset (bit)
res
Sub-Index
Index
LLLL
OOOO
rr
ss
IIII
e.g.
0020
0020
00
00
6030
Map 20h = 32bit starting at offset 20h = 32bit to
object
Default = 0020 0020 0000 6030h
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface
79 of 108