EM58 • HS58 • HM58 POWERLINK
This object is intended to show the number of physical distinguishable steps
each turn provided by the hardware (physical singleturn resolution).
If you want to set a custom resolution see the
object.
Default = 8192
for EM58 series
262144
for HS58 series
65536
for HM58 series
6502 Number of revolutions
[Unsigned16, ro]
WARNING
This object is active only if the bit 2
object is set to “=0”; otherwise it is ignored and the system uses
the custom values (
6001 Measuring units per revolution
measuring range in measuring units
) to calculate the position information.
This object is intended to show the number of physical distinguishable turns
provided by the hardware (number of physical revolutions).
The
Total hardware resolution
If you want to set a custom number of turns see the
and
6002 Total measuring range in measuring units
objects.
Default = 16384
for EM58 series
1
for HS58 series
16384
for HM58 series
6503 Alarms
[Unsigned16, ro]
Bit
Function
bit = 0
bit = 1
0 … 11
not used
12
Alarm not active
Alarm active
13
Alarm not active
Alarm active
14
Alarm not active
Alarm active
15
not used
This object provides further alarm messages. An alarm will be set if a
malfunction in the encoder could lead to incorrect position value. If an alarm
occurs, the according bit is set to logical high (1) until the alarm is cleared and
the encoder is able to provide an accurate position value.
The available alarm messages are listed here afterwards.
Machine data not valid
One or more parameters are not valid, set proper values to restore normal work
condition.
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface