EM58 • HS58 • HM58 POWERLINK
6001 Measuring units per revolution
[Unsigned32, rw]
WARNING
This object is active only if the bit 2
object is set to “=1”; otherwise it is ignored and the system uses
the physical values (
) to calculate the position information.
This object sets the custom number of measuring steps per revolution that are
output for the absolute singleturn position value.
If you enter an out-of-range value, the number of steps per revolution is forced
to the physical singleturn resolution.
To avoid counting errors, please check that:
= integer value.
6001 Measuring units per revolution
Allowed values must be less than or equal to the physical singleturn resolution
(
).
Default = 8192 (min. = 1, max. = 8192)
for EM58 series
262144 (min. = 1, max. = 262144)
for HS58 series
65536 (min. = 1, max. = 65536)
for HM58 series
WARNING
When you set a new value next to the
6001 Measuring units per revolution
object, please always check also the
object value and be sure that the resulting number of
revolutions complies with the physical number of revolutions of the device (see
the
object).
Let's suppose that the HM5816/16384PL encoder is programmed as follows:
6001 Measuring units per revolution
: 8192
6002 Total measuring range in measuring units
4096 (rev.)
Let's set a new singleturn resolution, for instance:
= 360.
6002 Total measuring range in measuring units
value at the same time, we will get the following result:
Number of revolutions
=
33,554,432 (
= 93,206.755...
360 (
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface
93 of 108