Chapter 8 Communication Functions
8-7
8.1.4 List of commands
Command
Main command
Command type
Classification
Items
Code ASCII code Code ASCII code
Treatment
Individual r(R)
H72
(H52)
SS 5353 Reads data from device of Bit, Byte, Word type.
Reading
device
Continuous
r(R)
H72
(H52)
SB 5342
Reads device Word in block unit.
(Continuous reading Bit is unavailable)
Individual w
(W)
H77
(H57)
SS 5353 Writes data to device of Bit, Byte and Word type.
Writing
device
Continuous
w(W)
H77
(H57)
SB 5342
Writes data to Byte and Word type in block unit.
(Continuous reading Bit is unavailable)
CPU
Status reading
r(R)
H73
(H53)
ST 5354
Reads flag list like PLC operation status and error
information.
Command
Main command
Register No.
Classification
Item
Code ASCII code
Register
no.
ASCII code
Treatment
Monitoring variable
register
x(X)
H78
H58
H00~H09 3030 ~ 3039 Register device to monitor.
Execution of
monitoring
y(Y)
H79
(H59)
H00~H09 3030 ~ 3039 Execute registered device to monitor.
Remark
MASTER-K120S main unit identifies capitals or small letters for main commands, but not for the others.
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...