Chapter 7 Usage of Various Functions
7-102
2) Error code
Error
code
Condition
Operation
Corrective action
H10
Acceleration time of basic parameter is out of range
Stop
Set Acceleration time within 0~10,000 range
H11
Deceleration time of basic parameter is out of range
Stop
Set Deceleration time within 0~10,000 range
H12
Speed limit of basic parameter is out of range
Stop
Set speed limit within 5~ 100,000 range.
H13
Bias speed of basic parameter is out of range
Stop
Set bias speed within 5 ~ 100,000 range.
H14
Backlash compensation of basic parameter is out of range
Stop
Set backlash compensation within 0~ 1,000 range
H15
JOG high speed of parameter is out of range
Stop
Set
JOG high speed within bias speed ~ speed limit
H16
JOG low speed of parameter is out of range
Stop
Set
JOG high speed within 5 ~ JOG high speed
H17
Origin return high speed of parameter is out of range
Stop
Set Origin return high speed within bias speed ~ speed limit
H18
Origin return low speed of parameter is out of range
Stop
Set Origin return low speed within bias speed ~ Origin return high speed
H19
Dwell time of parameter is out of range
Stop
Set Dwell time within 0 ~ 10000.
H20
Operation speed of positioning parameter is out of range
Stop
Set Operation speed within bias speed ~ speed limit
H21
Dwell time of pulse out parameter is out of range
Stop
Set
Dwell time of pulse out parameter within 0 ~ 10000
H30
POSIST command can’t be executed during operation
Operating
Check if positioning operation is executing when POSIST signal occur.
H31
POSIST command can’t be executed when output is prohibited
Stop
Check if output is prohibited when POSIST signal occur. Output can be
enabled by POSCTR command.
H32
POSIST command can’t be executed when origin is not
determined
Stop
Check if origin is not designated when POSIST signal occur.
Origin can be designated by POSORG or POSPRS command.
H33
Step No. of POSIST command can’t be over 20
Stop
Set step No. within 0~20
H34
POSDST command can’t be executed during operation
Operating
Check if positioning operation is executing when POSDST signal occur.
H35
POSDST command can’t be executed when output is
prohibited
Stop
Check if output is prohibited when POSDST signal occur. Output can be
enabled by POSCTR command.
H36
POSDST command can’t be executed when origin is not
determined
Stop
Check if origin is not designated when POSDST signal occur.
Origin can be designated by POSORG or POSPRS command.
H37
Operation speed of POSDST command is out of range
Stop
Set Operation speed within 5 ~ speed limit
H38
POSVEL command can’t be executed during operation
Operating
Check if positioning operation is executing when POSVEL signal occur.
H39
POSVEL command can’t be executed when output is
prohibited
Stop
Check if output is prohibited when POSVEL signal occur. Output can be
enabled by POSCTR command.
H3A
Operation speed of POSVEL command is out of range
Stop
Set Operation speed within 5 ~ speed limit
H3B
POSJOG command can’t be executed during operation
Operating
Check if positioning operation is executing when POSJOG signal occur.
H3C
POSJOG command can’t be executed when output is
prohibited
Stop
Check if output is prohibited when POSJOG signal occur. Output can be
enabled by POSCTR command.
H3D
Direction can’t be changed in JOG operation
Operating
Change direction after JOG operation end.
H3E
PWM command can’t be executed during operation
Operating
Check if positioning operation is executing when PWM signal occur.
H3F
PWM command can’t be executed when output is prohibited
Stop
Check if output is prohibited when PWM signal occur. Output can be enabled
by POSCTR command.
H40
PWM period of PWM command is out of range
Stop
Set period within 1 ~ 20,000
H41
Off duty of PWM command is out of range
Stop
Set duty within 0 ~ 100
H42
POSSOR command is available during operating only
Stop
Check if positioning operation is not executing when POSSOR signal occur.
H43
Speed override value of POSSOR command is out of range
Operating
Set override value within 5 ~ speed limit
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...