Chapter 7 Usage of Various Functions
7-75
3) Operation Mode
(1)
End Operation
A) With one time start command(rising edge of POSIST command), the positioning to the goal position is executed and
the positioning shall be completed at the same time as the dwell time proceeds.
B) This operation mode can be used as last positioning data of pattern operation.
C) Operation direction shall be determined by position address.
D) Operation action is trapezoid type operation that has acceleration, constant, deceleration section according to the
setting speed and position data.
[Example] End operation
•
Parameter setting
No. of program
start command
Step
No.
Coordinate
Operation
mode
Operation
method
Goal address
Speed
(pps)
Dwell time
(
㎳
)
1 1
Absolute
End Single
10,000
50,000 0
2 2
Absolute
End Single
20,000
20,000 0
3 3
Absolute
End Single
30,000
50,000 0
4 4
Absolute
End Single
40,000
20,000 0
Dwell time
Speed
Time
On
Start command
(POSIST
)
On
Start command
Operation
step no.: 1
Operation
step no.: 2
Operation
step no.: 3
Operation
step no.: 4
Time
Speed
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...