Chapter 7 Usage of Various Functions
7-98
8) Positioning direct start(POSDST)
Available device
Flag
Instruction
M P K L F T C S D
#
D
integer
No. of
steps
Error
(F110)
Zero
(F111)
Carry
(F112)
S
○
n1
○
○
○
○
○
○
○
○
SV1
○
○
○
○
○
○
○
○
○
○
SV2
○
○
○
○
○
○
○
○
○
○
9/11/13
○
S
Ch. for positioning direct start(0~1)
n1
Absolute/Incremental coordinate designation
(0:Absolute, 1:Incremental)
SV1
Positioning address
( -2,147,483,648 ~ 2,147,483,647)
Error
(F110)
Error flag turns on when designating area is over
and the instruction isn’t executed
SV2
Positioning speed (0 ~ 100,000pps)
■
POSDST S n1 SV1 SV2
(1) Functions
•
When input condition turns on(Rising edge), corresponding Ch. starts positioning by designated coordinate, address and speed
(2) Example program
•
When input condition(M0000) turns on, Ch. 0 outputs 100,000 pulses by designated coordinate(M0001), forward
direction and speed of 10kpps.
•
Acceleration/deceleration time is applied by corresponding parameter
POSDST
Positioning direct start
Designation
Flag set
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...