Chapter 7 Usage of Various Functions
7-91
7.3.4 Instructions
1) Positioning Indirect start(POSIST)
Available device
Flag
Instruction
M P K L F T C S D
#
D
integer
No. of
steps
Error
(F110)
Zero
(F111)
Carry
(F112)
S
○
n
○
○
○
○
○
○
○
○
○
○
5
○
S
Channel which is designated at parameter(0~1)
Starting step No.(0~20)
Error
(F110)
Error flag turns on when designating area is over
and the instruction isn’t executed
n
When designated as 0, starting step is increased
automatically
■
POSIST S n
(1) Functions
•
When input condition turns on, corresponding positioning control starts from assigned step No.
•
Positioning operation is edge triggered
.
(2) Example program
•
When input condition turns on, Ch.0 starts positioning from Step no.1
POSIST Positioning Indirect Start
Designation
Flag set
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...