Chapter 7 Usage of Various Functions
7-84
•
Timing diagram
1) Unused the M Code Output
2) Use the M Code
12) Error and Output Prohibition
•
Error includes Light failure error and Heavy failure error.
•
If light failure error occurs, the positioning operation will continue and only error will occur.
•
In case of heavy failure error, if the error is not cleared, it is not available to carry out the positioning operation. And if the
heavy failure error occurs during operation, the operation will stop.
•
If external high/low limit, external emergency stop during the positioning operation are detected during the positioning
operation, it stops promptly and becomes the pulse output prohibition status. Thus it is required to release the pulse
output prohibition by Error reset command(POSCTR)
•
For further information, please refer to Error code list .
Continues End
Positioning
Indirect start
Completed Flag
Current step M-th
step N-th
step
Continues End
Current step M-th
step N-th
step
Reset in the program
Reset in the program
M1911
M1912
Positioning
Indirect start
Completed Flag
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...