Chapter 7 Usage of Various Functions
7-88
(3) JOG speed
(A) JOG High Speed
•
JOG high speed operation has operation pattern as acceleration, constant speed, deceleration section. Therefore,
acceleration section and deceleration section is controlled by JOG acceleration/deceleration time.
•
JOG high speed setting range : 5
∼
100,000(unit: 1pps)
(notices when setting the high speed : Bias speed
≤
Jog high speed
≤
Speed limit)
(B) JOG Low Speed
•
JOG low speed operation has only constant speed operation pattern.
•
JOG low speed setting range : 5
∼
100,000 (unit: 1pps)
2) Positioning parameter
Here describes Positioning parameter
(1) Step No.
•
The setting range of positioning data as serial no. is 1
∼
20.
Remark
If step No. set to 0, operating step increase to next step automatically when current operation step finished