Chapter 7 Usage of Various Functions
7-76
(2) Keep
Operation
A) With one time Start command(POSIST), the positioning to the goal position of operation step is executed and the
positioning shall be completed at the same time as dwell time proceeds and without additional start command, the
positioning of operation step for (current operation step no. +1) shall be done.
B) Keep operation mode is available to execute several operation step in order.
C) Operation direction shall be determined by position address.
[ Example ] Keep operation
•
Parameter setting
No. of program
start command
Step
No.
Coordinate
Operation
mode
Operation
method
Goal address
Speed
(pps)
Dwell time
(
㎳
)
1 1
Absolute
Keep Single 10,000
50,000 10
2
Absolute
Keep Single 20,000
20,000 10
3
Absolute
End Single
30,000
50,000 0
2 4
Absolute
End Single
40,000
20,000 0
Dwell time
Dwell time
Speed
Time
On
Operation step 1
Start command
(POSIST)
Operation step 2
Operation step 1
Operation step 2
Содержание MASTER-K 120S Series
Страница 26: ...Chapter 4 Names of Parts 4 3 2 K7M DRT60U 3 K7M DT60U 4 1 2 40 points main unit Standard 1 K7M DR40U ...
Страница 27: ...Chapter 4 Names of Parts 4 4 2 K7M DRT40U 3 K7M DT40U 4 1 3 30 points main unit Standard 1 K7M DR30U ...
Страница 28: ...Chapter 4 Names of Parts 4 5 2 K7M DRT30U 3 K7M DT30U 4 1 4 20 points main unit Standard 1 K7M DR20U ...
Страница 29: ...Chapter 4 Names of Parts 4 6 2 K7M DRT20U 3 K7M DT20U 4 1 5 30 points main unit Economic 1 K7M DR30UE ...
Страница 138: ...Chapter 7 Usage of Various Functions 7 54 c Program ...
Страница 306: ...Appendix 3 External Dimensions App3 2 2 Slim type G7E DC08A G7E RY08A G7F ADHB G7F DA2V G7F RD2A ...