BCL 40
77
TNT
35/7-2
4
V
Detect code
9.3.2
"Online" Commands for System Control
Activate sensor input 1
Deactivate sensor input 1
Command
’CC’
Description
Reads the code type and contents of an unknown label without storing it
in Setup.
Parameter
no
Acknowledge-
ment
xxyyzzzzzz
The acknowledgement is the same as that of the "autoConfig" function.
Command
’+’
Description
Activates decoding (sensor input 1). A signal can be simulated on sensor
input 1 with this command.
Parameter
no
Acknowledge-
ment
no
Command
’-’
Description
Deactivates decoding (sensor input 1). A signal can be simulated on sen-
sor input 1 with this command.
Parameter
no
Acknowledge-
ment
no
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]