Communicating with the Device
Leuze
electronic
76
BCL 40
Leuze electronic
Manual definition of the reference code
Teach-In
Notice!
With this function, only code types are recognised that are identified using the "autoConfig"
function or which were set in the set-up.
©
After each reading via an ’RTx’ command, explicitly switch off the function again using
the ’RT-’ command since failure to do so will interfere with other commands as well as
prevent execution of a new ’RTx’ command.
Command
’RS’
Description
This command can be used to define a new reference code in the BCL 40
by means of direct entry via the serial interface. The data are saved in the
parameter set according to their input under reference code 1 or 2 and
stored in the working buffer for further processing.
Parameter
’RSyxxzzzzzzzz’
y, x and z are place holders (variables) for the actual input.
y:
def. reference code No
’1’ (Code 1)
’2’ (Code 2) …
xx def. code type (see command "’CA’" on page 75)
z
def. code information (1 … 31 characters)
Acknowledge-
ment
no
Example
input = ’RS10678654331’ (Code 1 (1), UPC (06), 78654331)
Command
’RT’
Description
This command enables a reference code to be defined quickly by reading
an example label.
Parameter
’RTy’
y:
Function
’1’ defines reference code 1
’2’ defines reference code 2
’-’ exit the Teach-In process
Acknowledge-
ment
zzzzzz Contents of the decoded label