Operation
Leuze
electronic
60
BCL 40
Leuze electronic
8
Operation
8.1
Display Elements
On the back side of the MA 10, there are 4 LEDs which display the momentary operating
status.
Status conditions of the LEDs
LED
Colour
Meaning
RDY
green
Ready
ERR
yellow
Error
ACT
red
Scanner active
DEC
green
Decoding successful
All four LEDs illuminate
• for approx. 0.5 second after connecting the operating voltage.
•
after accepting a "cold start" reset (> 4s) up until the reset button is released.
All four LEDs blink
• if the connection between the MA 10 and BCL 40 is interrupted.
RDY blinks
• during the "Power On" function test.
RDY illuminates
• when the devices are ready.
ERR illuminates
•
if a hardware error is encountered after the initialisation phase or in the case of a
serious software error.
RDY and ERR blink simultaneously
• when the setup program is activated.
Notice: No read operations can be carried out.
RDY and ERR blink alternately
• when the "autoConfig" function is activated by setting the corresponding
DIP switch.
•
when a reference code is defined (Teach-In).
ACT illuminates
• while the scanner is active, i.e. when the laser is in operation.
ACT blinks
• if a warning is output during the 'autoControl' function.
DEC illuminates
• for approx. 0.5 second after successfully completing a decoding process.