Commissioning
Leuze
electronic
58
BCL 40
Leuze electronic
7.3.4
Setting Parameters "Online"
The other possibility for setting the required operating parameters of the BCL 40 is through
"Online" programming via the integrated, two-language set-up program (English, German)
in the BCL 40.
Setup program
Using a PC (notebook) connected to the interface terminal, the menu-driven set-up program
can be called while in the service operating mode.
"Online" commands can then be directly entered that query data or carry out a software
reset.
Communication is carried out using a terminal program or more conveniently using the
Leuze configuration program.
A detailed description of the setup program along with all parameters which can be set, as
well as the most important "Online" commands can be found in chapter 9.
7.3.5
Setting the Bar Code Parameters Using "autoConfig"
The parameters of the bar codes which are to be read can be easily set using the function
"autoConfig".
In order to check the programmed bar codes, the BCL 40 should be connected to a data
terminal. The detection of the desired bar code(s) can be checked on the terminal.
Manual or "Online" activation
• The "autoConfig" function is activated on the MA 10 using DIP switch 2 (see figure 7.1
for the location of the DIP switch).
• The "autoConfig" function can be activated and deactivated via the serial interface
(host or service interface) using the "Online" commands 'CA+' (activate) and 'CA-'
(deactivate).
Details of "Online" commands can be found in chapter 9.
If "autoConfig" is active, the ERR LED and RDY LED on the MA 10 alternately blink.
Setting parameters
After activating the "autoConfig" function, the BCL 40 can read from one to eight example
labels containing the bar codes which are to be read. The BCL 40 decodes the labels and
displays, via the interface, the code type, the number of decoded characters and the char-
acter itself.
Number of labels to be decoded
While "autoConfig" is active, have the BCL 40 read as many labels in row as it will later
during a reading cycle when in normal operation. The number of labels can be set from "Set
Code" in the submenu "Decoding" of the setup program. The number of labels is limited to
8 when using the "autoConfig" program.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]