Current parameter set
In this parameter set, the current settings for all device parameters are stored. If the BCL 40
is in "stand alone" operation, the parameter set is stored in the EEPROM of the BCL 40. If
an MA 10 is also used, the parameter set is stored in EEPROM of the MA 10 and a copy
thereof in the EEPROM of the BCL 40. The current parameter set can be stored in three
ways:
• by changing and storing the current parameter set using the integrated SETUP pro-
gram of the BCL 40
• by copying (parameter "Download") a valid parameter set from the host computer
(e.g. a PC or PLC).
• by means of an off-line setup with the program "BCL Configuration Tool"
The current parameter set is loaded into the memory of the BCL 40:
• each time the supply voltage is connected
• after a "warm start" reset, as well as a software reset
Figure 7.2:
Block diagram storage concept for parameter sets
Notice!
By storing all current and customer-specific values in the connector unit MA 10, a connected
BCL 40 can be exchanged without difficulty since all parameters are maintained.
ROM
Default PS (2)
EEPROM
Current PS (0)
RAM
Working copy of current PS
ROM
Default PS (2)
EEPROM
Current PS (0)
RAM
Working copy of current PS
ROM
Customer-
specific
Parameter set (1)
EEPROM
Current
parameter set (0)
MA 10
BCL 40
BCL 40
Terminal
program on
PC
Parameter
"Down-
load" from
HOST
Parameter
"Download"
from HOST
Terminal
program on
PC
BCL 40
with MA 10
BCL 40 "Stand alone"
"2" = parameter set with factory default settings
"1" = customer-specific parameter set
"0" = current parameter set