9.2.2
Output menu
Figure 9.5:
"Output" menu
Option
Explanation
Output header
Select from the options listed below.
The output header is sent in a separate message before the read
result.
Label header
The Label header is set directly before the code data.
Label footer
The label footer is appended directly to the code data.
All labels in one
message
If this item is activated, all read codes are sent together with the output
header in a complete message.
-> The structure of this message string is depicted symbolically in the
preview window.
No read string
This character is set for each unrecognised bar code. Multiple charac-
ters (= string) may be entered here. Up to 20 characters are possible.
Properties
Set the desired formatting modes and formatting characters as
necessary.