![Leuze BCL 40 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/leuze/bcl-40/bcl-40_technical-description_1883763070.webp)
Communicating with the Device
Leuze
electronic
68
BCL 40
Leuze electronic
9.2.4
Communication
Figure 9.7:
"Communication" menu, standard setting
Select the desired baud rate, the stop bits, the data bits and the parity here. In addition,
several different handshake modes and protocols can be set here.
The RK512/3964 protocol can also be selected here. The individual parameters for this
protocol can be found in the tree-structure configuration and Communication -> Customer
Interface -> 3964 / RK 512 Protocol.
Attention!
If the BCL 40 is operated in a network ("Leuze multiNet"), no changes may be made here.
The scanner automatically sets itself to the multiNet protocol!
After equal scans
reach
If this item is activated, the read result is output immediately after the
bar code is decoded. If the item is deactivated, the read result is sent
only after the trigger signal is returned (= end of reading gate).
Time
For test purposes.
If the scanner is activated, the reading gate is automatically closed
by the scanner after this preset time has elapsed.
Scans without info
Following a successful read, the scanner waits for this number of
scans (sequential scans with no read result) before it automatically
deactivates itself.
Option
Explanation