electronic
Communicating with the Device
Leuze electronic
BCL 40
75
TNT
35/7-2
4
V
Call the setup program
Notice!
Read/write operations cannot be carried out in the service mode. The set-up program must
always be ended in order to return to normal operation.
"autoConfig"
Command
’E’
Description
Calls the set-up program. The main menu of the set-up program is dis-
played.
Parameter
no
Acknowledge-
ment
Acknowledgement, ’Load Parameter Set’
’ ’
’ Setup’
’-------------------------------------------------’
’ 1: Language’
’ 2: Decode Setup’
’ ’
’Enter:’
Command
’CA’
Description
Activates or deactivates the "autoConfig" function. Certain label reading
parameters are programmed automatically in the setup by the labels
which are read while the "autoConfig" function is active.
Parameter
’+’
activates "autoConfig"
’/’
rejects the last code read
’-’
deactivates "autoConfig" and stores the decoded data in the current
parameter set
Acknowledge-
ment
’xx yy zzzzzz’ (only with ’CA+’)
xx:
Code type of the read code
’01’ 2/5 Interleaved
’02’ Code 39
’06’ UPC (A, E)
’07’ EAN
’08’ Code 128, EAN 128
’10’ Add-on for EAN/UPC
’11’ Codabar
yy
No. of digits of the read code
zzzzzz
Contents of the decoded label. The
,
appears if the label was not
correctly read.