Installation
Leuze
electronic
38
BCL 40
Leuze electronic
6.3.1
Connecting the BCL 40 for "Stand Alone" Operation
If you would like to connect the BCL 40 for "stand alone" operation, you must make a corre-
sponding connector cable with a 15 pin Sub D plug (female) for the following connections:
• power supply of 18 … 36VDC, 5W max. power
• host RS 232 interface, or RS 485 when operating as a "multiNet slave"
• a sensor connection for triggering a read process
Figure 6.7:
Connecting the BCL 40 for "Stand Alone" Operation
Attention!
When using a normal 15 pin Sub D plug, the device only has a protection class of IP 54 in-
stead of IP 65!
Therefore, use the original Leuze cable from the accessories list. These cables are fitted
with a seal so that protection class IP 65 is maintained.
Switching inputs
A read process can be triggered by applying a voltage of 12 … 36VDC to the switched input
connections "Sensor 1A" and "Sensor 1B". The switched input maintains an electrical sepa-
ration of up to max. 250V.
15 pin
Sub D female
connector
Voltage supply
18 … 36VDC
Interface
Host RS 485 /
RS 232
RS 232 Terminal
interface for com-
missioning and
service
Sensor
connection
(photoelec. sen-
sor, key) for trig-
gering a read
process