Leuze
electronic
Installation
Leuze electronic
BCL 40
41
TNT
35/7-2
4
V
Open the MA 10 housing
©
Loosen the four Phillips screws on the back side of the MA 10 and carefully lift off the part
with the electronics on it.
The two halves of the housing are now connected to each other only by the ribbon cable.
You can now disconnect the ribbon cable from the electronic circuit board for
better access, as shown in
figure 6.10.
Figure 6.10: Disconnecting the ribbon cable inside the MA 10
©
To disconnect the ribbon cable, carefully press down the two latches of the ribbon cable
plug at the same time, as shown in figure 6.10 of
.
The cable is now free (
ó
in figure 6.10) and the half with the electronics and the connection
terminal can be removed for unhindered connection.
©
To reconnect the ribbon cable, insert the ribbon cable plug back into its socket, observing
the correct orientation, until it securely latches.
Notice!
All electrical connections can be carried out on the terminal strip quickly and without screw-
ing down or soldering. Wires with ferruled ends can be inserted directly into the terminal
without depressing the clamping lever.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]