Leuze
electronic
Commissioning
Leuze electronic
BCL 40
53
TNT
35/7-2
4
V
Notice!
If the BCL 40 is to be operated as a "stand alone" device, a reset is only possible via soft-
ware. There is a small green LED inside the BCL 40 at the lower edge of the reading window
that displays the operation readiness. The LED can also be used to monitor the operating
status of the BCL 40 in "stand alone" operation. During a reset, the LED remains dark and
continuously illuminates when the device is ready for operation.
7.2
Function Test
"Power On" test
After connecting the operating voltage, the devices carry out an automatic "Power On" func-
tion test. All four LEDs on the back of the MA 10 illuminate for approx. 1/2 second. During
software initialisation, the green "RDY" (ready) LED blinks.
Once the green "RDY" LED continuously illuminates, the device is ready for operation.
Interface
Proper function of the interface can be tested easiest in service operation using the service
interface with the "BCL Configuration Tool" software and a notebook computer.
"Online" commands
Using the "Online" commands, the important device functions can be checked, e.g. proper
functioning of the laser( see chapter 9 "Communicating with the Device").
Problems
Should problems occur during device commissioning, refer first to chapter 8.2. Should a
problem persist after checking all electrical connections and settings on the devices and
host, please contact a Leuze service office near you (see the back page of this operating
manual).
7.3
Setting the Parameters
You have now commissioned the BCL. Usually, you will have to configure it before you can
use it. Using the parameter options made available by the BCL, you may configure the BCL
to suit your individual area of application. For instructions regarding the various setting
options refer to chapter 9
or to the online help of the configuration software "BCL Configu-
ration Tool".
In order to operate the BCL, it is typically sufficient to set code type and code length in
accordance with the bar codes that are to be read. However, depending on the application,
you will configure the switching inputs and outputs according to your requirements.
The setting of code type and code length is usually accomplished by using the program "BCL
Configuration Tool", see chapter 9.2 "Graphic configuration using the "BCL Configuration
Tool" software".