Specifications
36
BCL 504
i
Leuze electronic
Power consumption
The energy requirement depends on the model:
• the line scanner with heating typically consumes 40W and a maximum of 50W power.
• the line scanner with oscillating mirror and heating typically consumes 60W and a
maximum of 75W.
These values are based on operation with unconnected switching outputs.
5.2.1
Line scanner with heating
Technical data same as for line scanner without heating with the following differences:
5.2.2
Oscillating-mirror scanner with heating
Technical data same as for line scanner without heating with the following differences:
Type
BCL 504
i
PROFIBUS DP
Type
Line scanner with heating
Electrical data
Operating voltage
24VDC ±20%
Power consumption
max. 50W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30min at +24VDC and an ambient temperature of -35°C
Min. conductor cross-section
Conductor cross-section of at least 0.75mm² for the supply-voltage supply line.
Wiring through of the voltage supply to multiple heating devices is
not
permissi-
ble.
Standard, M12 ready-made cable
not
usable
(insufficient cable cross-section)
Environmental data
Operating temperature range
-35°C … +40°C
Storage temperature range
-20°C … +70°C
Table 5.4:
Specifications of the BCL 504
i
line scanners with heating
Type
BCL 504
i
PROFIBUS DP
Type
Oscillating-mirror scanner with heating
Optical data
Useful opening angle
max. 50°
Max. swivel angle
±12°(adjustable)
Electrical data
Operating voltage
24VDC ±20%
Power consumption
max. 75W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30min at +24VDC and an ambient temperature of -35°C
Table 5.5:
Specifications of the BCL 504
i
oscillating-mirror scanners with heating